Biomass Steam Boilers CE Certification Process

 

1.1 Pre-Certification

Biomass Steam Boilers CE certication process is quite complicated, below are a few
key points. Thus everyone may have a preliminary understanding of the certification
process.
The company shall firstly select a suitable authorized body (Noti ed Body) and entrust
them to carry on the certification over biomass steam boilers. Specific certification mode is determined by the two parties through consultation.

1.2 Data to be Submitted for Certification

After signing the contract, NB will request the manufacturer to submit data for
conformation, including basic data of manufacturer, basic data of the biomass steam
boilers, list of major parts, main mechanical and electrical drawings, related calculation book, welder and NDE personnel quali cation, major pressure part material certificate, risk assessment analysis report, description of safety protection device in mechanical system, product self-declaration (conformity statement), etc. After conformation of these data, NB will perform relevant on-site inspection, including personnel, equipment, steam boiler performance test, etc. They will issue relevant certi cates after conforming compliance with the requirement of each directive.

1.3 Design Standard for Certified biomass steam boilers

As mentioned earlier, PED is not a mandatory technical standard, it only stipulates basic safety requirements for the biomass boiler. The manufacturer can select a design and manufacture standard according to the actual situation. For export steam boiler, domestic manufacturers generally choose ASME code for design and manufacture, since it is relatively close to the requirements of foreign countries. Some users need biomass steam boiler with ASME stamp, so manufacturer will choose ASME code as the basis for design.

技术6

1.4 Material Requirements for Certified biomass steam boilers

No material from non-EU countries (including ASME materials) has yet been approved in
Europe or produced in accordance with European standard. Hence in practice, the
material for pressure part is selected via material evaluation and Particular Material
Appraisal
by NB.

1.5 Electrical Directives

For small steam boiler, the motor of water pump, fan and oil pump shall have CE
certificate
. Other electrical parts (such as solenoid valve, transformer, etc.) whose
service voltage is within the directive (AC 50-1000V, DC 75-1500V) also need CE
certificate.
In addition, LVD specifically requires an emergency stop button on the control panel.
The emergency stop button shall be able to cut o the power supply at the fastest
speed.

1.6 MD Directives

European Union’s requirements for the machinery safety is equally stringent. All risk-prone areas shall have warning label, the pipeline shall indicate the fluid type and direction. NB inspectors will timely put forward during certification, and manufacturers shall rectify according to the provisions.

1.7 Final CE Certification Result

After all the design, manufacturing, test, compliance review are quali ed, CE certification
of small biomass boiler is over. The biomass steam boilers meeting EU export condition
shall have EMC certificate, MD certificate, B certificate, F certificate. The nameplate shall have PED nameplate and MD nameplate, and PED nameplate shall have CE mark with NB code.

Wade Zhang

CEO of Taishan Group Taian Boao International Trade Co., Ltd. 30 years experience in Global industrial boiler market,  Over 300 boiler projects experience, including 21+ EPC projects. Projects span 30+ countries & regions, involving industries such as nuclear power, energy & electricity, municipal heating, mining, textiles, tires etc.
Scroll to Top
Taishan Group
Make an appointment with us to meet at exhibition
Quick Contact

Get Quick Support